Industrial Generators For Sale

Browse Dependable New & Used Industrial Generators2,000 kW Generators for Sale

At Turnkey Industries, we aim to make it easy to find quality new and used generators for the job site. Below, you can find 2,000 kW generators for sale from brands such as Caterpillar and Cummins. We know these generators help a wide range of industries, from hospitals to construction sites, so we ensure you have the best selection to choose from. Feel free to browse the list below to learn more, such as each machine’s hours, main breaker amps, and enclosure type. Whether you’re looking for 2,000 kW generators with 100 hours or 1,000 hours, you can search the list below to find a solid match. Reach out to Turnkey Industries when you’re ready to add one of these machines to your inventory.

2000 kW Generators for Large Plants, Hospital Systems, Data Centers, and More

A 2000 kW generator serves large industrial facilities, hospitals and data centers during outages. Its capacity covers air conditioning, heating, refrigeration, manufacturing equipment and lighting, plus essential emergency equipment such as pumps, life support systems and communication devices.

Frequently Deployed in Parallel for Data Center Redundancy

At 2000 kW, single-unit deployment becomes less common for the largest data centers — instead, facilities often run multiple units in parallel, with N+1 or 2N redundancy configurations that keep the site fully powered even if one generator goes down for maintenance or fails unexpectedly. This is also where uptime commitments in colocation and hyperscale contracts start driving generator specification directly, since a facility’s SLA obligations can dictate not just total capacity but how many independent units are required to meet contractual redundancy standards.

Strategic Sizing for 2000 kW Duty

At 2000 kW the load study is usually shared between the owner, the electrical engineer and the utility. Gather the single-line drawing, the largest motor start and the target transfer time, then confirm that one set, or several in parallel, meets the requirement. Our power calculator supports early estimates before that engagement. Use our amperage chart to find output current at your service voltage.

Gas Service Versus Refueling Plans at 2000 kW

Diesel and natural gas sets are both built at 2000 kW, and the choice changes what has to be on site before the generator arrives: a tank and a refueling plan for diesel, or a gas service sized for the engine. For diesel, our diesel fuel consumption chart shows a 2000 kW set using 42.8 gal/hr when a quarter loaded, 72.2 gal/hr at half load, 103.5 gal/hr at three-quarters, and 141.9 gal/hr at 100%. Figures for a specific engine can differ from the chart: mtu’s spec sheet for the 16V4000 DS2000 lists 143 gal/hr at 100% of its standby rating, 106 gal/hr at 75%, and 74 gal/hr at 50%, and names #2 diesel or HVO as the recommended fuel. For natural gas, the diesel chart does not apply, and its page says so. Jenbacher lists its J612 gas genset at up to 2,078 kW for 60 Hz, at 480V to 13.8kV, with electrical efficiency up to 45.2%. Jenbacher does not publish gas flow or inlet pressure on that page and notes its data depends on gas quality and ambient conditions, so those numbers have to come from the data sheet for the exact unit. To see one fuel only, use the industrial diesel generators page or the industrial natural gas generators page.

Crane Lift, Airflow, and Housing for 2000 kW Sets

A 2000 kW set is normally lifted by crane onto its pad or into a building, so the rigging plan starts with the shipping weight and the housing you choose. Weight to plan around: mtu lists the 16V4000 DS2000 open power unit at 47,523 lb, measuring 254.9 in. long, 99.9 in. wide, and 135.2 in. high. mtu calls these estimates for an open 480 volt unit and says lengths may vary with other voltages; an enclosure or sub-base tank adds to both. What comes on the skid: The standard DS2000 package sits on a structural steel base with a unit-mounted radiator. At its 50 °C (122 °F) radiator rating, that radiator needs 111,890 SCFM of cooling air, so any housing or generator room has to pass that much air. Noise and housing type: Open, the set measures 98.7 dB(A) at 7 m (23 ft) at full standby load. Weather enclosures, sound-attenuated enclosures, walk-in enclosures, and containers are the options for bringing that down; request the enclosure drawing and its weight along with the unit. Containers on the gas side: Jenbacher states that its gensets can be installed inside a building or inside a container, and its containerized scope includes the ventilation, cooling, and lube oil supply systems. Seismic and code: 2021 IBC seismic certification and HCAI pre-approval are optional on the DS2000. Before delivery day, confirm crane reach and capacity, road access for an oversize load, and that the pad matches the base drawing for your configuration; the shipping and returns policy sets out our freight terms.

Buying One 2000 kW Set or a Parallel Group Changes the Math

Each of these changes what a 2000 kW unit costs.
  • Voltage and current: For 2000 kW, our amperage chart shows 3015 amps at 480V and 348 amps at 4160V, and lists 208V as Unavailable. mtu’s DS2000 sheet gives 3,007 amps at 480V and 347 amps at 4,160V. The voltage you need sets the alternator, breaker, and cable sizes. Run your numbers through our power calculators first.
  • Housing: An open skid, a sound-attenuated enclosure, a walk-in enclosure, and a container are different builds at different costs.
  • One unit or several: Sites that parallel two or more sets for redundancy also need paralleling controls and switchgear.
  • Rating and run hours: mtu approves the DS2000 standby rating for an average output of up to 85% over 24 hours, with no overload capability. If the set will run for long stretches, price a prime or continuous rating instead.
  • New or pre-owned: Compare new generators and used generators on hours, maintenance records, and remaining warranty; mtu’s basic limited warranty on this model is two years or 3,000 hours.
  • Rigging and transport: Crane time, oversize-load permits, and distance to the site.
Pricing for a 2000 kW unit is handled through our contact us page.

Sustained Energy Flow for 2000 kW Operations

A 2000 kW generator can carry an entire plant or campus during an outage. Because a failure at that scale is expensive, buyers weigh redundancy, fuel supply and service access as heavily as the kW figure.

Hyperscale Redundancy Needs Versus Lower Demand at 2000 kW

Facilities below hyperscale redundancy needs may be served by our 1500 kW generator. For the largest industrial complexes or more capacity, our 2,500 kW generator is the next step up.

Support From Quote Through Service on 2000 kW Units

Heavy, sustained use is what 2000 kW generators are built for, and Turnkey Industries pairs each sale with customer service and support afterward. Buying a 2000 kW generator is a project, and we have been supplying generators for ten years. Each unit is inspected and covered by the 30-day IronClad warranty, and our service and maintenance team can assist after installation. Your questions are welcome through contact us; the inventory lists our generators.

Our Commercial Generator Selection for Large Facilities

Discover the comprehensive range of commercial generators at Turnkey Industries, where we offer a variety of options to meet diverse power requirements. Our collection spans from compact 50 kW generators to high-capacity 2,000 kW units, providing reliable power solutions for businesses of all sizes. The 50 kW generators are perfect for smaller commercial applications, such as boutique retail stores, small offices, or modest industrial setups, ensuring steady power for essential operations. If you require more power, our 2,500 kW generators can support large manufacturing facilities, expansive data centers, or significant commercial complexes. These larger units are designed to handle heavy loads and deliver consistent performance, even in challenging conditions.

Data Center Redundancy, SLAs, and Cooling Air at 2000 kW

Parallel 2000 kW Sets for Data Center Redundancy

Redundancy configurations like N+1 or 2N ensure the facility stays fully powered even if one unit is down for maintenance or fails — a common requirement in colocation and hyperscale contracts.

Do uptime SLAs affect what generator capacity a data center needs?

Yes. Contractual uptime commitments often dictate not just total power capacity, but the number of independent redundant units required to meet the agreement.

Large-Scale Redundancy Configurations at 2000 kW

Capacity for large-scale redundancy setups. Facilities with more modest needs may find our 1500 kW generator sufficient.

What lies above 2000 kW in your range?

Our 2,500 kW generator is the step up, for the largest industrial complexes and sites that need still more capacity.

How much cooling air does the mtu 16V4000 DS2000 need?

At its 50 °C (122 °F) radiator rating it needs 111,890 SCFM, so any housing or generator room has to pass that much air.
24-7 Support

Need Help Finding What You’re Looking For?

Give One of Our Experts a Call!

Get in touch for more info about this unit!

Just fill out the form below or call us 713-823-0890

…Or Call Us 713-823-0890

red web icon

Worldwide

Delivery

hand with dollar tag

Best Price

Guaranteed

hand showing available supply

Immediate

Availability

IronClad certified badge

IronClad

Certified