Shop new & used inventory of industrial backup generators 350 kW GENERATORS FOR SALE
In our commitment to meeting a diverse range of applications, Turnkey Industries offers industrial generators in various sizes. Featured below are premium 350 kW generators available for purchase. Each generator in our inventory undergoes thorough testing and inspection by certified experts, ensuring your peace of mind during the purchase process. Additionally, we provide 350 kW diesel generators with varying operational hours, ranging from zero to 10,000. Click on the options below to explore more details, including enclosure type, fuel tank size, breaker availability, and more. If you have additional questions or are prepared to purchase one of our 350 kW generators, feel free to contact us today.
Not finding what you’re looking for? Let us help!
GENERATOR SERVICE & REPAIR
Keep your equipment running peak performance with preventive maintenance and repair.
Subscribe For Inventory Updates
We promise not to blow up your
inbox!
350 kW Generators for Manufacturing Equipment, Mining Operations, Large Facilities, and More
Large manufacturing plants, construction sites and mining operations use 350 kW generators for primary power, and hospitals, data centers and other critical facilities use them for backup. Outdoor events such as music festivals or temporary campsites also rely on this size for lighting and sound systems.Why Redundancy Starts to Matter at This Capacity
Once a facility’s backup power needs reach 350 kW, a single point of failure becomes a much bigger risk than it is at smaller sizes — there’s simply more riding on that one unit staying online. This is where paralleling multiple generators, rather than relying on one large unit, starts to make sense for critical operations like hospitals and data centers. Running two or more units in parallel means the facility can lose one generator to maintenance or failure without losing power entirely, and it lets capacity scale incrementally as a facility grows rather than requiring a full unit replacement.Selecting 350 kW: Requirement Examination
Sizing at 350 kW raises a second question: whether one set carries the load or two smaller sets in parallel offer more flexibility and redundancy. Know the total peak load, the critical portion, and how much downtime the operation can tolerate. Our power calculator can frame that conversation with an engineer. For breaker and cable planning, check the current at your voltage on our amperage chart.Paralleling Gear on Gas-Fueled Towable 350 kW Sets
Towable sets near this size often come with load-sharing hardware built in, so two or more can be parked side by side and run as one source. Generac Mobile’s MGG450 is a gaseous trailer unit rated at 360 kW prime and 300 kW continuous on natural gas at 60 Hz. Its spec sheet lists:- Load sharing: Up to 32 additional gensets, kW and kVAr sharing, automatic hour run balancing, dead bus sensing, and a motorized breaker for parallel running.
- Running gear: Three 8000 lb axles with electric brakes, a 3 in lunette ring hitch, and NATM compliance.
- Size on the trailer: 15,281 lb operating weight; 253 x 102 x 131 in (L x W x H).
- Fuel feed: Natural gas, wellhead gas, or LP with automatic NG/LP changeover, at 5-50 psig for commercial-quality gas.
- Noise: 84 dB(A) at 23 ft.
Fueling One 350 kW Set or Several in Parallel
Whether you plan to run one 350 kW set or tie several together, the fuel decision shapes the controls, the site work, and how long the system can carry load. Diesel sets carry their own fuel on site. Kohler’s 350REOZJC, a Tier 3 EPA-certified unit for stationary emergency use, lists 26.5 gph at 100% of its standby rating and 13.7 gph at 50%. Kohler also approves certified renewable HVO/RD fuel for this model and notes that volumetric consumption can run up to 4% higher on it. For a size-based diesel reference, the 350 kW line of our diesel fuel consumption chart reads 7.9 gal/hr at 1/4 load, 13.1 at 1/2, 18.7 at 3/4, and 25.1 at full load. Those values cover diesel only. The chart is not meant to be used for natural gas sets. Natural gas sets draw from a utility line. Caterpillar’s DG350, built on the 18.1 L Cat CG18 engine and EPA certified for emergency and non-emergency use, lists 3962 CFH at full standby load. Cat calls for 1.25 to 1.5 psi at the genset base frame rail connection as standard, with an optional low-pressure version that runs on 0.25 to 1.5 psi, so confirm the pressure your gas utility can deliver before you pick a model. On our amperage chart, a 350 kW generator draws 1220 amps at 208V and 527 amps at 480V. If you are splitting load across paralleled units, run your numbers through the power calculators first. Diesel generators and natural gas generators are listed separately.Paralleling Hardware Raises the Stakes on 350 kW Quotes
If you are planning a paralleled system, cost depends on the switchgear and controls as much as on the generator. Points worth pricing out:- Controller level: On the Kohler 350REOZJC, paralleling comes from the APM603 or Decision-Maker 6000 controller. Either can manage up to 8 generators on an isolated bus, but only with other units using the same controller, so check what your existing sets have before buying.
- Paralleling hardware: Kohler offers an electrically operated breaker and voltage sensing as options for paralleled installs. Each unit you add needs its own.
- Duty rating: The same Kohler set is listed at 350 kW standby and 320 kW prime at 480V. Prime allows unlimited hours at varying load, while standby allows no overload. Buy for the duty you will run.
- Enclosure and tank package: Weather housing, Level 1 or Level 2 sound housing, and subbase fuel tanks are each separate line items.
- New or pre-owned: Compare new industrial generators with used industrial generators; hours, service history, and how closely matched the units are all matter in a paralleled lineup.
- Freight and setup: Distance to your site and the work needed to place and connect each unit add to the total.
Questions About a 350 kW Purchase: Where to Start
For the last decade, Turnkey Industries has honed its expertise in providing tailor-made generator solutions that meet the distinct needs of each client.Power Potential Across Our Commercial Generator Range
A 350 kW generator for sale fuels large-scale industrial operations. One step down, the 250 kW generator serves mid-sized enterprises, and the 100 kW generator suits smaller ventures.Parallel Operation, Outdoor Events, and Gas Use at 350 kW
Redundancy Through Several 350 kW Sets
Paralleling multiple units adds redundancy — if one generator needs maintenance or fails, the others keep the facility powered. It also allows capacity to scale incrementally as needs grow.Is a 350 kW generator suitable for outdoor events?
Yes. It’s a common size for large festivals or temporary campsites needing reliable power for lighting, sound, and support equipment across a sizable footprint.What industries most commonly need 350 kW of backup power?
Large manufacturing plants, construction sites, mining operations, hospitals, and data centers are among the most common applications at this capacity.Can Generac MGG450 units run in parallel?
Yes. Its sheet lists load sharing with up to 32 additional gensets, plus a motorized breaker for parallel running.DG350 Gas Draw and Base Frame Pressure
Cat lists 3,962 CFH at full standby load, with 1.25 to 1.5 psi at the base frame rail connection as standard.Shop Industrial Generators By kW
- 20kW-99kW Industrial Generators
- 100kW-499kW Industrial Generators
- 500kW-999kW Industrial Generators
- 1000kW-1499kW Industrial Generators
- 1500kW-1999kW Industrial Generators
- 2000kW-3000kW Industrial Generators
- See All Sizes >
