Browse New & Used inventory of 600 kw industrial generators 600 kW GENERATORS FOR SALE
In our commitment to address a broad spectrum of applications, Turnkey Industries offers industrial generators in various sizes. Featured below are premium 600 kW generators available for purchase. Each generator in our inventory undergoes rigorous testing and inspection by certified experts, ensuring your peace of mind throughout the purchasing process. Similarly, we provide 600 kW diesel generators with varying operational hours, ranging from zero to 10,000. Explore the options below to delve into more details, such as enclosure type, fuel tank size, breaker availability, and other specifications. For any additional inquiries or if you are prepared to acquire one of our 600 kW generators, please don’t hesitate to reach out to us today.
Not finding what you’re looking for? Let us help!
GENERATOR SERVICE & REPAIR
Keep your equipment running peak performance with preventive maintenance and repair.
Subscribe For Inventory Updates
We promise not to blow up your
inbox!
600 kW Generators Capable of Powering Large Plants, Campuses, Building Systems, and More
Office complexes, healthcare, telecommunications, data centers and large manufacturing facilities are among the places a 600 kW generator keeps running. Its capacity also suits motor, pump and fan loads in commercial, industrial and agricultural settings, and it serves as backup when utility power fails.Anchoring a Multi-Building Campus on One 600 kW Set
600 kW frequently marks the size where a single generator can realistically cover an entire small campus rather than one building at a time — university buildings clustered together, a hospital with several connected wings, or a manufacturing site with multiple structures sharing infrastructure. The advantage of anchoring at this size instead of running several smaller units per building is simpler electrical distribution and fewer points of maintenance, though it does mean more is riding on that single generator staying operational.Assessment Behind a 600 kW Selection
At 600 kW the enclosure, fuel supply and transfer arrangement have to be settled along with the kW figure. Collect the load total, voltage, allowed outage time and site space limits in one place before comparing units. Our power calculator can confirm the numbers before a specialist does final sizing. Our amperage chart shows what a 600 kW set delivers in amps at each voltage it lists.HVO, Diesel, and Gas Inlet Pressure at 600 kW
Most 600 kW units on the market burn either diesel or natural gas, and the choice shapes how you plan fuel supply, permits, and where the set sits. The fuel type is listed on each unit. Start with our industrial diesel generators or our industrial natural gas generators. Diesel at 600 kW Our diesel fuel consumption chart lists a 600 kW generator at 13.2 gal/hr at 1/4 load, 22 gal/hr at 1/2 load, 31.5 gal/hr at 3/4 load, and 42.8 gal/hr at full load. Those rows cover diesel sets in general and do not apply to natural gas units. For one specific model, Kohler’s spec sheet for the 600REOZVB (TWD1643GE engine) shows 42.7 gph at 100% of its standby rating and 21.0 gph at 50%. Kohler adds that volumetric fuel consumption can run up to 4% higher on HVO or renewable diesel than on #2 ULSD. Natural gas at 600 kW A gas set draws from a utility line rather than an on-site tank, so the service line and meter have to keep up with full load. Cummins lists its C600N6 (600 kW standby, EPA SI NSPS stationary emergency certified) at 9557 standard cubic feet per hour (CFH) at full load and 5424 CFH at half load, with fuel inlet pressure at the regulator of 14 to 20 in. WC. Other gas models use different amounts and pressures, so check the sheet for the unit you pick. Output current On our amperage chart, the 600 kW row reads 2080 amps at 208V and 902 amps at 480V. Our power calculators can help you check whether your load fits before you compare units.Weather and Sound Housings: Noise and Weight at 600 kW
At this size, picking a weather housing or a sound housing changes two things at once: noise at the property line and the weight your crane and pad have to carry. Kohler’s published data for the 600REOZVB shows how far apart the options sit.- Open set: Without a housing, Kohler lists the 600REOZVB at 4229 x 1829 x 1985 mm (166.5 x 72.0 x 78.1 in.) and up to 4885 kg (10770 lb.) wet.
- Weather enclosure: In steel with no tank, the package is listed at up to 6212 kg (13695 lb.) and 91 dB(A) at full load. The aluminum version comes in at 5588 kg (12320 lb.).
- Sound enclosure: The steel sound package with no tank is listed at 6368 kg (14040 lb.) and 76 dB(A); aluminum is 5745 kg (12665 lb.). Kohler takes these readings as a log average of 8 positions at 7 m (23 ft).
- Footprint: Either housing without a tank measures 6045 x 1883 x 2455 mm (238 x 74 x 97 in.).
- Tank underneath: With the 2049 L (541 gal.) sub-base tank, which Kohler estimates at 12 hours of full-load supply, the steel sound package rises to 7712 kg (17003 lb.). A 7645 L (2019 gal.) tank is rated for an estimated 48 hours.
Pricing a 600 kW Set Starts With the Housing
A 600 kW quote reflects the following decisions.- Housing: Open skid, weather enclosure, or sound enclosure, and steel or aluminum panels. On the Kohler 600REOZVB, those choices run from 91 dB(A) down to 76 dB(A) and add weight that shows up in freight.
- Standby or prime duty: Kohler rates the 600REOZVB at up to 600 kW standby and up to 555 kW prime, so a site that needs prime power may need a different unit than a standby-only site.
- Emissions certification: The 600REOZVB is EPA Tier 2 certified for stationary emergency applications. A set certified for other uses is a different build.
- Tank size: A sub-base tank sized for about 12 hours and a 72-hour state-code tank (11554 L, 3052 gal., on Kohler’s sheet) are separate options.
- Fuel: Diesel and natural gas units carry different equipment, from the fuel tank on a diesel set to the gas train on a gas set.
- Condition: Compare new generators with used generators; run hours and build year also count on a used set.
- Freight and setting: Distance, crane time, and pad work are part of the delivered cost.
Steadfast Energy Sources During Outages at 600 kW
Plants at 600 kW commonly run several large motors on one service. When the utility drops, a standby set of this size restarts them from its own supply and hands back through the transfer switch once the utility is stable.Single Large Building or Multi-Structure Campus at 600 kW
A single large building rather than a multi-structure campus may be covered by our 500 kW generator. Anchoring power for several connected buildings or a growing industrial site is where our 750 kW generator adds margin.Inspected 600 kW Units With 30-Day Coverage
Inspection is the foundation of our 600 kW offering. The 30-day IronClad warranty covers every unit, and our service and maintenance team is on hand for the life of the equipment. For a decade, buyers have relied on us for these assurances. Read through the inventory or write to us.Power Solutions: Customizing Generator Capacities to Meet Diverse Industry Requirements
Around 600 kW generators for sale, the lineup scales both ways: 80 kW generators for medium-sized enterprises and 150 kW generators for commercial establishments, with 600 kW serving large-scale industrial needs.Multi-Building Power, Single-Unit Risk, and Noise at 600 kW
Can one 600 kW generator power multiple buildings?
Yes, provided the buildings share electrical infrastructure. It’s a common approach for campuses and multi-wing facilities that want simpler distribution and fewer maintenance points than running separate smaller units per building.What’s the tradeoff of anchoring power to a single large generator?
Simpler infrastructure and maintenance, but more depends on that one unit staying operational. Facilities with zero tolerance for downtime sometimes offset this with a secondary backup unit or paralleled systems.Multi-Building Footprints Beyond 500 kW
A larger multi-building footprint. When the facility is nearer to one large building, our 500 kW generator may be enough.Several Connected Buildings on One Generator
If your site is growing or already spans several connected buildings, our 750 kW generator provides more headroom.How loud is the Kohler 600REOZVB in each housing?
Kohler lists 91 dB(A) at full load in the steel weather enclosure and 76 dB(A) in the steel sound enclosure.Shop Industrial Generators By kW
- 20kW-99kW Industrial Generators
- 100kW-499kW Industrial Generators
- 500kW-999kW Industrial Generators
- 1000kW-1499kW Industrial Generators
- 1500kW-1999kW Industrial Generators
- 2000kW-3000kW Industrial Generators
- See All Sizes >
